INITIAL SETTINGS 04_01 zute parametre postavi iz kolone C
MODIF. INICIJALNA PODEŠAVANJA MENU 04 MODE STAND-BY ON
SETTINGS TECHNIC TEHNIČKA PODEŠAVANJA N-8-1 TYPE PELLET
UBACIVANJE PELETA N-8-1-01 LOAD PELET 00 0 0 n-8-1-01___09
VREMENSKI INTERVAL IZMEDJU ZAUSTAVLJANA I PONOVNOG POKRETANJA PUZA
N-8-2 TYPE CHIMNEY BRZINA VENTILATORA N-8-2-01 ECXAUST CHIMNEY
03 0 3 n-8-2-01___00 probao razne brzine i nista bolje LINEARNO
POVECAVA ILI SMANJUJE OBRTAJE VENT. U SVIM REZIMIMA ZA 50 OBRTAJA
N-8-3 BANK DATA 0 0 BANK DATA A9 SERVICE MENY A9 ULAZAK
U SERVISNI MENI N-8-04 SETTINGS GENERAL GLAVNA PODEŠAVANJA
N-8-04-01 HALT RESTART 05' n-8-4-01___05 VREME ZA KOJE PEĆ NE
MOŽE DA SE UGASI NA TASTER ON/OFF OD KAD SE UKLJUČI N-8-04-02
ASP-MIN SPENTO 05' n-8-4-02___03 MIN VREME RADA VENT. DIMNIH GAS.
KOD ISKLJUCENJA PEĆI, AKO JE T IZDU. GAS. MANJA OD ZADATE U PR28
N-8-04-03 PRELOAD LIGHT 60'' n-8-4-03___50 VREME POČETNOG
UBACIVANJA PELETI PRILIKOM UKLJUČIVANJA PEĆI N-8-04-04 WAITING
FIRE 100'' n-8-4-04___100 VREME ZA DETEKCIJU PRVOG PLAMENA
N-8-04-05 EXH-SPEE PRELOAD 1850 n-8-4-05___1800 BROJ OBRTAJA
MOTORA ZA ODVOD DIMNIH GASOVA PRILIKOM POČETNOG UBACIVANJA PELETA.
N-8-04-06 DIFFEREN OFF AUTO 04.0C n-8-4-06___02,0 RAZLIKA T
PRILIKOM UKLJUČENJA STAND - BY MODA N-8-04-07 DEL-OFF AUTO 02'
n-8-4-07___02' VREME ZA KOJE SE PEĆ GASI U STAND - BY MODU, TJ
KADA DETEKTUJE RAZLIKU T KOLIKO VREM. JE POTR. DO ISKLJ. PEĆI
N-8-04-08 CHANGE OUTPUT 20'' n-8-4-08___32 VREME PRELASKA IZ
PROGRAMA U PROGRAM. OBJAŠNJENJE DATO DETALJNIJE U NASTAVKU UPUSTVA
N-8-04-09 EXCHANG CLEANING 225U n-8-4-09___225u FUNKCIJE ZA
UKLJUČ. I ISKLJUČ. PEĆI NEKIM UREĐAJEM ZA KOMUNIK. ( NPR. MOB.
TEL.BLUETOOTH ) N-8-04-10 FROZEN KEYBORD OFF n-8-4-10___off
BLOKADA TASTERA ( UKLJUČIVANJE ISKLJUČIVANJE DUGMIĆIMA SET I
ON/OFF OFF N-8-04-11 BLACK OUT 30'' n-8-4-11___30 VREME ZA KOJE
PRI NASILNOM ISKLJ. PEĆI IZ EL. MREŽE ( NEST.STRUJE) NEĆE DOĆI DO
JAVLJ.GREŠKE N-8-04-12 TIME SERVICE OFF n-8-4-12___off VREME
SERVISA N-8-04-13 MODO STAND BY 0 2 n-8-4-13___01 Koju
temperaturu prati (juri) : 1-temperatura vazduha; 2-temperatura vode;
3-temperatura termostata N-8-06 SETTINGS FACTORY PODEŠAVANJA
PARAMETRA N-8-06-01 MINUTES TIME OUT 22'' n-8-6-01___15'
MAKSIMALNO VREME PALJENJA PEĆI ( NE PALI SE ALARM 05 ) N-8-06-02
MINUTI START 02' _____02____02' VREME POTREBNO DA SE DETEKTUJE T
IZDUVNIH GASOVA VEZANO SA PR13 N-8-06-03 CADENCE CLEANING 11'
_____03___20 INTERVAL VREMENA IZMEĐU ČIŠĆENJA POSUDA U KOJOJ SE
VRŠI SAGOREVANJE N-8-06-04 AUGER LIGHTS 0.8' _____04___1.1 VREME
UBACIVANJA PELETA U REŽIMU PALJENJA N-8-06-05 COCLEA START 1.2'
_____05___1.1 VREME UBACIVANJA PELETA OD TRENUTKA KADA SE
VERIFIKUJE PLAMEN DO ULASKA U REŽIM RADA N-8-06-06 COCLEA POWER1
1.3'' _____06___1.8 VREME UBACIVANJA PELETA U REŽIMU 1 ( PROGRAM 1
) N-8-06-07 COCLEA POWER2 2.0'' _____07___2.2 VREME UBACIVANJA
PELETA U REŽIMU 2 ( PROGRAM 2 ) N-8-06-08 COCLEA POWER3 3.0''
_____08___3.3 VREME UBACIVANJA PELETA U REŽIMU 3 ( PROGRAM 3 )
N-8-06-09 COCLEA POWER4 3.7'' _____09___4.6 VREME UBACIVANJA
PELETA U REŽIMU 4 ( PROGRAM 4 ) N-8-06-10 COCLEA POWER5 4.2''
_____10___5.7 VREME UBACIVANJA PELETA U REŽIMU 5 ( PROGRAM 5 )
N-8-06-11 DELAY ALARMS 30'' _____11___30 VREME ČEKANJA
IZBACIVANJA GREŠKE OD TRENUTKA KADA SE GREŠKA DETEKTUJE N-8-06-12
DURATION CLEANING 65'' _____12___65 VREME ČIŠĆENJA POSUDE U
KOJOJ SE VRŠI SAGOREVANJE N-8-06-13 THRESHOL MINIMUM 40C
_____13___50 MINIMALNA T IZDUVNIH GASOVA KADA PEC ULAZI U WORK
REZIM N-8-06-14 THRESHOL MAXIMUM 220C _____14___220 MAKSIMALNA T
IZDUVNIH GASOVA - KADA DOSTIGNE OVU T PEĆ SE VRAĆA U PROGRAM 1
N-8-06-15 THRESOL BLOWER 60C _____15___93 KADA T IZDUVNIH GAS.
PREĐE OVU VREDNOST ONDA SE UKLJUČUJE VENT. ZA IZDUV. U PROSTORIJU
N-8-06-16 EXHAUST EN-START 2500 _____16___2250 BROJ OBRTAJA
VENTILATORA IZDUVNIH GASOVA U REŽIMU PALJENJA N-8-06-17 EXHAUST
ENGI-AVV 2700 _____17___2800 BROJ OBR. VENT. IZDUVNIH GAS. OD
TREN. KADA SE VERIFIKUJE PLAMEN DO ULASKA U REŽIM RADA N-8-06-18
EXHAUST ENGINE1 1650 _____18___1750 BROJ OBRTAJA VENTILATORA
IZDUVNIH GASOVA U REŽIMU 1 ( PROGRAM 1 ) N-8-06-19 EXHAUST ENGINE2
1850 _____19___1950 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U
REŽIMU 2 ( PROGRAM 2 ) N-8-06-20 EXHAUST ENGINE3 2070
_____20___2200 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 3
( PROGRAM 3 ) N-8-06-21 EXHAUST ENGINE4 2350 _____21___2450 BROJ
OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 4 ( PROGRAM 4 )
N-8-06-22 EXHAUST ENGINE5 2550 _____22___2700 BROJ OBRTAJA
VENTILATORA IZDUVNIH GASOVA U REŽIMU 5 ( PROGRAM 5 ) N-8-06-23
ENCODER ON _____23___on UKLJUČIVANJE ENKODERA N-8-06-24 TIME
BREAKING 0.2'' _____24___0.2 VREME UBACIVANJA PELETA PRILIKOM
ČIŠĆENJA POSUDE ZA SAGOREVANJE N-8-06-25 TRESHOL PUMP 50C
_____25___47C T NA KOJOJ SE UKLJUČUJE PUMPA N-8-06-26 EXCLUED
PRESSURE ON _____26___on ISKLJUČIVANJE SIGURNOSNOG MANOMETRA
N-8-06-27 TRESHOL PRESSION 2.5B _____27___2,5b PRITISAK NA KOME SE
ISKLJUČUJE KOTAO N-8-06-28 TRESHOL OFF 70C _____28___90C KADA T
IZDUVNIH GAS.PADNE ISPOD OVE T PEĆ PRESTAJE SA IZDUVAVANJEM KOJE SE
VRŠI PRILIKOM ISKLJUČ. PEĆI N-8-06-29 EXH-SPEE CLEANING 2800
_____29___2800 BRZINA VENT. IZDUVNIH GA. PRILIKOM ISKLJUČIVANJA
PEĆI I ČIŠĆENJA POSUDE U KOJOJ SE VRŠI SAGOREVANJE N-8-06-30
AUGER CLEANING 0.5'' _____30___2.2 VREME UKLJUČIVANJA DOZATORA
POSLE ISKLJUČENJA N-8-06-31 SPEED BLOW1 130u _____31___130U
N-8-06-32 SPEED BLOW2 150u _____32___150U N-8-06-33 SPEED BLOW3
170u _____33___170U N-8-06-34 SPEED BLOW4 185u _____34___185U
N-8-06-35 SPEED BLOW5 225u _____35___225U N-8-7 RESET
PAR-TIME
alfa plam commo 21
visina plafona 2.60m
prizemlje 65m2(rebra 32+20+8+susac+commo 21)stiropor 8cm
Sprat 58m2(rebra 20+12+12+8+susac)krov min.vina 20cm