Ljudi ovo su moji parametri koje mi je postavio serviser, ukoliko mislite da nesto treba da se promeni molim za sugestije. Hvala
N-8-1-01 LOAD PELET 0 0 VREMENSKI INTERVAL IZMEDJU ZAUSTAVLJANA I PONOVNOG POKRETANJA PUZA
N-8-2-01 ECXAUST CHIMNEY 0 0 LINEARNO POVECAVA ILI SMANJUJE OBRTAJE VENT. U SVIM REZIMIMA ZA 50 OBRTAJA
N-8-04-01 HALT RESTART 05' VREME ZA KOJE PEĆ NE MOŽE DA SE UGASI NA TASTER ON/OFF OD KAD SE UKLJUČI
N-8-04-02 ASP-MIN SPENTO 10' MIN VREME RADA VENT. DIMNIH GAS. KOD ISKLJUCENJA PEĆI, AKO JE T IZDU. GAS. MANJA OD ZADATE U PR28
N-8-04-03 PRELOAD LIgGHT 50'' VREME POČETNOG UBACIVANJA PELETI PRILIKOM UKLJUČIVANJA PEĆI
N-8-04-04 WAITING FIRE 100'' VREME ZA DETEKCIJU PRVOG PLAMENA
N-8-04-05 EXH-SPEE PRELOAD 1800 BROJ OBRTAJA MOTORA ZA ODVOD DIMNIH GASOVA PRILIKOM POČETNOG UBACIVANJA PELETA.
N-8-04-06 DIFFEREN OFF AUTO RAZLIKA T PRILIKOM UKLJUČENJA STAND - BY MODA
N-8-04-07 DEL-OFF AUTO 2C VREME ZA KOJE SE PEĆ GASI U STAND - BY MODU, TJ KADA DETEKTUJE RAZLIKU T KOLIKO VREM. JE POTR. DO ISKLJ. PEĆI
N-8-04-08 CHANGE OUTPUT 20'' VREME PRELASKA IZ PROGRAMA U PROGRAM. OBJAŠNJENJE DATO DETALJNIJE U NASTAVKU UPUSTVA
N-8-04-09 EXCHANG CLEANING 200U FUNKCIJE ZA UKLJUČ. I ISKLJUČ. PEĆI NEKIM UREĐAJEM ZA KOMUNIK. ( NPR. MOB. TEL.BLUETOOTH )
N-8-04-10 FROZEN KEYBORD OFF BLOKADA TASTERA ( UKLJUČIVANJE ISKLJUČIVANJE DUGMIĆIMA SET I ON/OFF OFF
N-8-04-11 BLACK OUT 30'' VREME ZA KOJE PRI NASILNOM ISKLJ. PEĆI IZ EL. MREŽE ( NEST.STRUJE) NEĆE DOĆI DO JAVLJ.GREŠKE
N-8-04-12 TIME SERVICE OFF VREME SERVISA
N-8-04-13 MODO STAND BY 0 1
N-8-06-01 MINUTES TIME OUT 18' MAKSIMALNO VREME PALJENJA PEĆI ( NE PALI SE ALARM 05 )
N-8-06-02 MINUTI START 2' VREME POTREBNO DA SE DETEKTUJE T IZDUVNIH GASOVA VEZANO SA PR13
N-8-06-03 CADENCE CLEANING 45' INTERVAL VREMENA IZMEĐU ČIŠĆENJA POSUDA U KOJOJ SE VRŠI SAGOREVANJE
N-8-06-04 AUGER LIGHTS 1,1' VREME UBACIVANJA PELETA U REŽIMU PALJENJA
N-8-06-05 COCLEA START 1.1' VREME UBACIVANJA PELETA OD TRENUTKA KADA SE VERIFIKUJE PLAMEN DO ULASKA U REŽIM RADA
N-8-06-06 COCLEA POWER1 1.2 VREME UBACIVANJA PELETA U REŽIMU 1
N-8-06-07 COCLEA POWER2 1.9 VREME UBACIVANJA PELETA U REŽIMU 2
N-8-06-08 COCLEA POWER3 2.5 VREME UBACIVANJA PELETA U REŽIMU 3
N-8-06-09 COCLEA POWER4 3.2 VREME UBACIVANJA PELETA U REŽIMU 4
N-8-06-10 COCLEA POWER5 3.8 VREME UBACIVANJA PELETA U REŽIMU 5
N-8-06-11 DELAY ALARMS 30'' VREME ČEKANJA IZBACIVANJA GREŠKE OD TRENUTKA KADA SE GREŠKA DETEKTUJE
N-8-06-12 DURATION CLEANING 60'' VREME ČIŠĆENJA POSUDE U KOJOJ SE VRŠI SAGOREVANJE
N-8-06-13 THRESHOL MINIMUM 43C MINIMALNA T IZDUVNIH GASOVA KADA PEC ULAZI U WORK REZIM
N-8-06-14 THRESHOL MAXIMUM 200C MAKSIMALNA T IZDUVNIH GASOVA - KADA DOSTIGNE OVU T PEĆ SE VRAĆA U PROGRAM 1
N-8-06-15 THRESOL BLOWER 60C KADA T IZDUVNIH GAS. PREĐE OVU VREDNOST ONDA SE UKLJUČUJE VENT. ZA IZDUV. U PROSTORIJU
N-8-06-16 EXHAUST EN-START 2250 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU PALJENJA
N-8-06-17 EXHAUST ENGI-AVV 2650 BROJ OBR. VENT. IZDUVNIH GAS. OD TREN. KADA SE VERIFIKUJE PLAMEN DO ULASKA U REŽIM RADA
N-8-06-18 EXHAUST ENGINE1 1400 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 1
N-8-06-19 EXHAUST ENGINE2 1650 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 2
N-8-06-20 EXHAUST ENGINE3 1850 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 3
N-8-06-21 EXHAUST ENGINE4 2100 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 4
N-8-06-22 EXHAUST ENGINE5 2600 BROJ OBRTAJA VENTILATORA IZDUVNIH GASOVA U REŽIMU 5
N-8-06-23 ENCODER ON UKLJUČIVANJE ENKODERA
N-8-06-24 TIME BREAKING 0.2'' VREME UBACIVANJA PELETA PRILIKOM ČIŠĆENJA POSUDE ZA SAGOREVANJE
N-8-06-25 TRESHOL PUMP 50C T NA KOJOJ SE UKLJUČUJE PUMPA
N-8-06-26 EXCLUED PRESSURE ON ISKLJUČIVANJE SIGURNOSNOG MANOMETRA
N-8-06-27 TRESHOL PRESSION 2.5B PRITISAK NA KOME SE ISKLJUČUJE KOTAO
N-8-06-28 TRESHOL OFF 70C KADA T IZDUVNIH GAS.PADNE ISPOD OVE T PEĆ PRESTAJE SA IZDUVAVANJEM KOJE SE VRŠI PRILIKOM ISKLJUČ. PEĆI
N-8-06-29 EXH-SPEE CLEANING 2800 BRZINA VENT. IZDUVNIH GA. PRILIKOM ISKLJUČIVANJA PEĆI I ČIŠĆENJA POSUDE U KOJOJ SE VRŠI SAGOREVANJE
N-8-06-30 AUGER CLEANING 0.5'' VREME UKLJUČIVANJA DOZATORA POSLE ISKLJUČENJA
N-8-06-31 SPEED BLOW1 130u
N-8-06-32 SPEED BLOW2 150u
N-8-06-33 SPEED BLOW3 170u
N-8-06-34 SPEED BLOW4 185u
N-8-06-35 SPEED BLOW5 225u
Alfa Commo 15
Stan 65m2
4 radijatora
120x60
120x60
110x60
60x60
Sušač
Caleffi antikondenzacioni ventil na 55C